Portable Calibrator Versa

Easy and efficient calibration of ergometers

Part number: 919940
To Specifications

Portable Calibrator Versa

The Calibrator Versa is an easy to set up and very accurate portable calibration station. The calibration station is controlled by a PC or laptop. With this station it is possible to control or calibrate all existing ergometers accurately. The Lode Calibrator is mounted on the axis of the ergometer. This system is approved by an independent institute, and is used by calibration institutes all over the world since 1993. Calibrations can be done up to 750 watt. Due to the possibilities you create when using a normal PC to calibrate the calibrator you can print a calibration report for your customer and/or create your own database of calibration data. The Calibrator Ultra is the essential tool for professionally and efficiently servicing ergometers.

The Calibrator Versa is the next development in professional portable calibration equipment, coming from a pedigree of 2 decades of calibration devices supporting accurate ergometry.

Please note, specifications at 110 V are different than at 230 V.

Highlight

Lode Device Manager

This sophisticated software offers easily and efficiently analysis of possible issues and solve those, like updating the embedded software. Only service engineers of official Lode Distributors that have followed the specific training are eligable for registration.

Features

Extremely Accurate Calibration of Ergometers

Highly accurate calibration of ergometers is possible with this product

Professional Service Tool

Lode provides tools for service engineers of distributors that are completely dedicated to its products and purpose. Some can even be used for non-Lode calibration activities

Universal Calibration

This tool can be used for Calibration of Lode products as well as products of other manufacturers

Multiple ergometer axis connectors available

Various accessories are available to connect the calibrator to most available ergometers

USB connectivity

USB to connect to PC or ECG or ergospirometry products facilitates easy connectivity.

Related products

Calibrator Ultra

Portable Calibrator Ultra

Lode Device Manager

  • Specifications
  • Support
  • Workload
  • Accuracy
  • User Interface
  • Connectivity
  • Dimensions
  • Power requirements
  • Standards & Safety
  • Environmental conditions

Workload

minimum rotational speed 25 rpm calibrator minimum rotations
maximum rotational speed 180 rpm calibrator maximum rotations
rotation direction clockwise looking at the outgoing axis
rotation direction anti-clockwise looking at the outgoing axis
maximum motor torque 55 Nm the maximum torque the motor can deliver
maximum sensor torque 100 Nm the maximum torque the sensor can measure
warming up time 5 min the time to bring the product on operational temperature
approved power range (maximum) 750 W power range for which use is approved
approved power range (minimum) 0 W power range for which use is approved
power range at maximum rpm (maximum) 750 W operational power range
power range at maximum rpm (minimum) 0 W operational power range
crank adapter included to connect crank to calibrator

Accuracy

speed accuracy 0.8 % accuracy of speed
power accuracy error > 100 W 1 % accuracy of power application
power accuracy error up to 100W 1 W accuracy of power application
torque resolution 0.05 Nm resolution of the torque adjustment
time resolving 10 ms resolving time of the calibrator
accuracy rpm adjustment 1.0 rpm the accuracy of the rotational speed adjustment
rpm resolution 1 rpm resolution of the rotational speed

User Interface

Software available in English Software available in English
Software available in German Software available in German
Software available in Dutch Software available in Dutch
Software available in Japanese Software available in Japanese

Connectivity

RS232 in connector connection via RS232

Dimensions

cable length 3000 mm (118.1 inch) length of cable
product length (cm) 52 cm (20.5 inch) length of product in cm
product width (cm) 32 cm (12.6 inch) width of the product in cm
product height 52 cm (20.5 inch) height of product
product weight 29 kg (63.9 lbs) the weight of the product

Power requirements

230 VAC 10 A Power requirement at 230 VAC
110 VAC 15 A Power requirements at 110 VAC
Phases 1 phases
Frequency 50/60 Hz frequency in Herz

Standards & Safety

integrated emergency stop emergency stop fully integrated

Environmental conditions

minimum operational temperature 5 °C minimum temperature at which the device will work within specification
maximum operational temperature 40 °C maximum temperature at which the device will work within specification
minimum operational air pressure 80 kPa minimum airpressure as from which the product will be operating within specification
maximum operational air pressure 106 kPa maximum air pressure as from which the product will be operating within specification
minimum operational non-condensing humidity 30 % minimum non-condensing humidity at which the product will operate within specification
maximum operational non-condensing humidity 90 % maximum non-condensing humidity at which the product will operate within specification
minimum storage & transport temperature -20 °C minimum temperature the product may be stored and transported at
maximum storage & transport temperature 60 °C maximum temperature the product may be stored or transported at
minimum air pressure storage & transport 50 kPa minimum air pressure the product may be stored or transported at
maximum storage & transport air pressure 106 kPa maximum air pressure the product may be stored and transported at
min. humidity storage & transport 10 % minimum non-condensing humidity that the product can be stored or transport at
max. humidity storage & transport 95 % max. non-condensing humidity that the product can be stored or transported at
Mìnimum safe temperature 5 °C Minimum ambient temperature at which the device can be used safely
Maximum safe temperature 40 °C Maximum ambient temperature at which the device can be used safely

Certificates

CE Certificate Stress Test and Force Measurement Devices

ISO 9001:2015 Certificate

ISO 13485: 2016 Certificate

CB Certificate Calibrator ULTRA and Verso

Frequently asked questions

What is the difference between static (manual) and dynamic calibration?

A static calibration is used for some ergometers to check the assumed linear relationship between 2 workload points with use of weights. This type of calibration is not accurate because the driving gear is not taken into account and the relationship is not totally linear at higher and lower workloads. Historically mechanical ergometers are calibrated by this method the accuracy is shifting a lot between tests because the belt-length (mechanical braking part) is influenced by heatening. Static calibration is not fulfilling any relevant norm. Dynamic calibration is performed by a service engineer with a calibrator. The ergometer is calibrated at the axis in the total workload and rpm range (instead of 2 points without any movement of the driving gear). The data can be compared with the initial calibration report from the factory to check drifting in time. A calibration report is printed for the customer and stored by the service engineer. Dynamic calibration performed with a Lode calibrator is accurate and fulfills all relevant norms and certifications.

I have no communication with the Calibrator using a USB to Serial interface.

Although the Windows OS might say it automatically finds the correct drivers for the USB to Serial interface we recomment to install the latest drivers from the CD that came with the USB to Serial interface or from the website of the manufacturer of the USB to Serial interface. This might prevent a lot of trouble.

Is Lode recommending special disinfection procedures for the Lode products due to COVID-19?

Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!

Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.