Portable Calibrator VERSA 110V: Precise ergometry calibration on the go
Ensure the accuracy of your ergometry equipment with the Portable Calibrator VERSA 110V. Designed for specialists, this compact and reliable calibrator simplifies on-site testing and calibration of ergometers and treadmills. Its portable design and high precision make it the ideal solution for labs, hospitals, and sports performance centers. Built to meet international standards, the VERSA 110V ensures consistent performance and optimal equipment reliability. Upgrade your calibration process with this essential tool for professionals.
Explore our range of calibration tools to ensure the best performance of your ergometry equipment.
Highlight
High standards
Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.
Feature
Extremely Accurate Calibration of Ergometers
Highly accurate calibration of ergometers is possible with this product
Professional Service Tool
Lode provides tools for service engineers of distributors that are completely dedicated to its products and purpose. Some can even be used for non-Lode calibration activities
Universal Calibration
This tool can be used for Calibration of Lode products as well as products of other manufacturers
Multiple ergometer axis connectors available
Various accessories are available to connect the calibrator to most available ergometers
USB connectivity
USB to connect to PC or ECG or ergospirometry products facilitates easy connectivity.
- Specifications
- Support
Workload
| minimum rotational speed | 25 rpm | calibrator minimum rotations |
|---|---|---|
| maximum rotational speed | 180 rpm | calibrator maximum rotations |
| rotation direction clockwise | looking at the outgoing axis | |
| rotation direction anti-clockwise | looking at the outgoing axis | |
| maximum motor torque | 55 Nm | the maximum torque the motor can deliver |
| maximum sensor torque | 100 Nm | the maximum torque the sensor can measure |
| warming up time | 5 min | the time to bring the product on operational temperature |
| approved power range (maximum) | 750 W | power range for which use is approved |
| approved power range (minimum) | 0 W | power range for which use is approved |
| power range at maximum rpm (maximum) | 750 W | operational power range |
| power range at maximum rpm (minimum) | 0 W | operational power range |
| crank adapter included | to connect crank to calibrator |
Accuracy
| speed accuracy | 0.8 % | accuracy of speed |
|---|---|---|
| power accuracy error > 100 W | 1 % | accuracy of power application |
| power accuracy error up to 100W | 1 W | accuracy of power application |
| torque resolution | 0.05 Nm | resolution of the torque adjustment |
| time resolving | 10 ms | resolving time of the calibrator |
| accuracy rpm adjustment | 1.0 rpm | the accuracy of the rotational speed adjustment |
| rpm resolution | 1 rpm | resolution of the rotational speed |
User Interface
| Software available in English | Software available in English | |
|---|---|---|
| Software available in German | Software available in German | |
| Software available in Dutch | Software available in Dutch | |
| Software available in Japanese | Software available in Japanese |
Connectivity
| USB connector | connection via USB possible | |
|---|---|---|
| RS232 in connector | connection via RS232 |
Dimensions
| cable length | 3000 mm (118.11 inch) | length of cable |
|---|---|---|
| product length (cm) | 52 cm (20.47 inch) | length of product in cm |
| product width (cm) | 32 cm (12.6 inch) | width of the product in cm |
| product height | 52 cm (20.47 inch) | height of product |
| product weight | 24 kg (10.89 lbs) | the weight of the product |
Power requirements
| V AC | 100 - 240 V | voltage in Volt |
|---|---|---|
| Phases | 1 | phases |
Standards & Safety
| integrated emergency stop | emergency stop fully integrated |
|---|
Environmental conditions
| minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification |
|---|---|---|
| maximum operational temperature | 35 °C | maximum temperature at which the device will work within specification |
| minimum operational air pressure | 80 kPa | minimum airpressure as from which the product will be operating within specification |
| maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification |
| minimum operational non-condensing humidity | 30 % | minimum non-condensing humidity at which the product will operate within specification |
| maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification |
| minimum storage & transport temperature | -20 °C | minimum temperature the product may be stored and transported at |
| maximum storage & transport temperature | 60 °C | maximum temperature the product may be stored or transported at |
| minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at |
| maximum storage & transport air pressure | 106 kPa | maximum air pressure the product may be stored and transported at |
| min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at |
| max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at |
Manuals
Manual Calibrator Ultra English
Date of publication: April 8, 2025
Frequently asked questions
What is the difference between static (manual) and dynamic calibration?
A static calibration is used for some ergometers to check the assumed linear relationship between 2 workload points with use of weights. This type of calibration is not accurate because the driving gear is not taken into account and the relationship is not totally linear at higher and lower workloads. Historically mechanical ergometers are calibrated by this method the accuracy is shifting a lot between tests because the belt-length (mechanical braking part) is influenced by heatening. Static calibration is not fulfilling any relevant norm. Dynamic calibration is performed by a service engineer with a calibrator. The ergometer is calibrated at the axis in the total workload and rpm range (instead of 2 points without any movement of the driving gear). The data can be compared with the initial calibration report from the factory to check drifting in time. A calibration report is printed for the customer and stored by the service engineer. Dynamic calibration performed with a Lode calibrator is accurate and fulfills all relevant norms and certifications.
I have no communication with the Calibrator using a USB to Serial interface.
Although the Windows OS might say it automatically finds the correct drivers for the USB to Serial interface we recomment to install the latest drivers from the CD that came with the USB to Serial interface or from the website of the manufacturer of the USB to Serial interface. This might prevent a lot of trouble.
Is Lode recommending special disinfection procedures for the Lode products due to COVID-19?
Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!
Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.