LCRM upgrade from 2.x.x to 3.x.x

Part number: U950902
To Specifications

Highlight

Easy to install

– Simple step by step installer
– Easy setup of ergometers
– Easy setup of subjects

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Multifunctional software for all Lode ergometers

The software can be used for all Lode ergometers and treadmills, including their options like bloodpressure, heart rate, SpO2 etc.
Load as well as bloodpressure triggers can be set remotely.

Complete setup

The modular structure of the software combined with the accurate and reliable Lode ergometers offers a complete and modern ergometry setting.

Feature

Original Accessory

Accessory designed and manufactured according to the Lode company quality standards

  • Support

LCRM Demo Software

950902 LCRM 3.4.1 demo software

Certificates

CE Certificate Monitoring Devices for Cardiac Rehabilitation

Frequently asked questions

Will my existing Lode streamers and ergometers still be compatible when I upgrade the LCRM software to a newer version?

Yes you can upgrade to a newer LCRM version without any influence on the total LCRM installation, The Lode Streamers, ergometers and treadmills will work as usual.

How do I recharge the battery of the ECG streamer?

Besides charging the device with the USB charge cable (950792), there is a docking station (950840, optional) to charge four streamers at the same time. The red light indicates the state of the battery charging. This light is on during charging and off when charging finished.

How should I place the electrodes to obtain a proper Lead I and lead II ECG signal?

Placement of the electrodes: Red: right arm, 1st intercostal space, avoiding thick muscle Yellow: left arm, 1st intercostal space, avoiding thick muscle Green: left leg, 6th intercostal space Black: right leg ground electrode, 6th intercostal space Lead I: Red Electrode (right arm) and Yellow Electrode (left arm) Lead II: Red Electrode (right arm) and Green Electrode (left leg) See manual m950920 chapter 7 for a picture of the electrode placement.

Is it possible to lower the workload in case of a sudden SpO2 drop?

SpO2 can be used to control the load of the ergometer. In the tab “SpO2 ” you can choose to use SpO2 for automatic load adjustment and you can edit the settings (see manual LCRM 950902)

How is the LCRM software dealing with privacy and GPDR regulations?

Since LCRM software version 3.0, deactivate, reactivate and remove actions are logged on username, action and id number of the operator; because of privacy and GPDR regulations names and date of births are not logged. The logfiles can be found in %appdata%/lode/lcrm as AuditLod.csv.

Do I need a new license for the upgrade to a newer version of LCRM?

Yes you will need a new license to upgrade LCRM. This license can be supplied by the Lode service support. You may need to order this via your distributor

Is an upgrade to a newer version of LCRM for free?

An upgrade to a newer version of software will give you more functionality, it’s not for free.
An update will give you small improvements and bug fixes, this is for free.