Productafbeelding CARDIO with HUR SmartTouch Ergometer

CARDIO with HUR SmartTouch Ergometer

A cutting-edge medical and rehabilitation device designed to offer unparalleled precision and customization for training.

Part number: 960906
To Specifications

CARDIO with HUR SmartTouch Ergometer

The HUR SmartTouch system stands out as a globally renowned choice among healthcare professionals. In the case of HUR Smart Touch devices, the key aspect is that they are specifically designed to collaborate with the HUR Smart Touch system. Personalized workouts can be set up, targeting the demographic of healthy aging and rehabilitation. The system records training sessions, allowing for the tracking of progress over time.  With its 7-watt startup load, this equipment enables individuals with lower strength capacity to engage in training. Employing an eddy current electro-magnetic braking system, this ergometer excels in precision, aligning seamlessly with Lode’s commitment to accuracy. It offers a versatile workload adjustment spanning from 7 to 1000 watts. The ultralow step-through design ensures effortless access, while its cutting-edge ergonomic layout guarantees an optimal positioning for users. Furthermore, it operates with minimal noise levels.

Why the CARDIO with HUR SmartTouch Ergometer?

Q-factor equal to road-bike

The Q-factor of the ergometer is equal to the Q-factor of road bikes, creating perfect training circumstances.

Rotatable handlebar with new lever

The new designed lever makes it even easier to adjust the handlebar. The handlebar can be rotated 360 degrees and is constructed in such a way that the test subject can be installed comfortably at every seating height.

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Product features

7 inch display

This ergometer is standard supplied with a large 7 inch touch screen display.

Extreme low start up load

The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.

Low noise

Due to accurate manufacturing and the careful choice of materials the product has an extremely low noise level.

Accurate over a long period of time

The Lode ergometers are supplied with an electro-magnetic braking mechanism of Lanooy (eddy current). The biggest advantage of this braking system compared to a friction braking system is the absolute accuracy and the accuracy over time. Moreover, friction braking systems have more wearing parts.

Readout of saddle height

The height of the saddle is stepless adjustable and can be read-out on the saddle shaft

Perfect ergonomic position

Improved ergonomic position according to the latest requirements.

Ultra-low step-through

The lowest possible step-through guarantees easy access to the ergometer for all test subjects: a must for people who are not so mobile!

Hidden connectors

The cables are connected to the ergometer under the ergometer, which means that the test subject or operator cannot bump onto the connector.

Bluetooth connectivity

Bluetooth connectivity allows for secure short and medium range connectivity of peripherals.

Related products

HUR by Lode Recumbent

CARDIO with HUR SmartTouch Recumbent Ergometer

CARDIO-with-HUR-SmartTouch-Treadmill

CARDIO with HUR SmartTouch Treadmill

Cardio with HUR by Lode Arm ergometer

CARDIO with HUR SmartTouch Arm Ergometer

967926 Hur by Lode Angio adjustable wallfixation

CARDIO with HUR SmartTouch Arm Ergometer with adjustable wall fixation

What are the advantages of HUR SmartTouch?

The incorporation of Lode devices into the SmartTouch ecosystem represents an advancement in the field of medical and rehabilitation equipment. This seamless integration establishes an unified network of medical devices and software, greatly enhancing the overall patient care experience and simplifying the rehabilitation process.

Within this integrated ecosystem, healthcare professionals gain access to a single platform that consolidates data from a variety of medical devices. The HUR devices can be used for resistance training and for cardio when combined with our Lode devices. In order to contribute collaboratively to the broader perspective of the rehabilitation/healthy aging of individuals. This junction provides a comprehensive view of patient progress, health metrics, and treatment history, offering healthcare providers real-time insights.

The seamless data sharing and interoperability among these devices significantly improve the efficiency and accuracy of patient care, facilitating personalized and well-coordinated training  plans. In essence, this integration revolutionizes medical technology, resulting in patient-centred rehabilitation outcomes and a higher standard of care.

Tailoring the CARDIO with HUR SmartTouch Ergometer to your needs

While the 7″ display and the usage of the HUR Smart Touch system on your ergometer is already a valuable tool for monitoring your workout, we understand that everyone has unique needs. To cater to this diversity, we offer several exciting options to elevate your ergometer experience:

Heart Rate (HR) Belt Bluetooth Compatibility: Through the integration of HR belt Bluetooth functionality, the ergometer seamlessly synchronizes with compatible heart rate monitors. This capability not only provides immediate heart rate data but also facilitates monitoring and analysis of the patient’s performance. This gives an insight into the fitness of the patient and enables you to adjust future training sessions.

Electric Adjustable Saddle Height: Easily fine-tune the saddle height for your perfect ergonomic position. This feature is key for ensuring comfort, preventing strain, and facilitating ease of use. It’s particularly helpful for users with varying mobility levels.

Saddle Extra Large: Enjoy maximum comfort with an extra-large, cushioned saddle. Ideal for users needing superior seating Say goodbye to discomfort and focus on your workout.

Program functionality: Unlock a world of possibilities by adding program functionality to your 7″ display. With a range of pre-set programs, you can tailor your sessions to your goals. These programs offer structured guidance, ensuring efficient and effective training. You are also able to use the protocols from the Smart Touch.

These customizable features empower you to customize an ergometer that perfectly suits your specific needs, enhancing the workout experience while accuracy in achieving the fitness objectives of the patients. As the ergometer continues to evolve, these options underscore our commitment to helping them achieve their goals with precision and convenience

  • Specifications
  • Science
  • Support
  • Marketing
  • Workload
  • Accuracy
  • Comfort
  • User Interface
  • Connectivity
  • Dimensions
  • Power requirements
  • Standards & Safety
  • Certification
  • Environmental conditions

Workload

workload range fixed torque 0,1 - 70 Nm Workload range in fixed torque mode
minimum load 7 W the minimum load the ergometer can provide
maximum peak load 1000 W the maximum load the ergometer can provide for a short period of time
minimum load increments 1 W the smallest steps with which the load can be added
maximum continuous load 750 W the maximum power the ergometer can deliver continuous
hyperbolic workload control control of workload in hyperbolic way
linear workload control control ergometer in a linear way
fixed torque workload control control ergometer in a fixed torque way
maximum rpm independent constant load 150 rpm rpm as to which constant load can be applied
minimum rpm independent constant load 30 rpm rpm as from which constant load can be applied
optional heart rate controlled workload control the device optionally through a set heartrate
electromagnetic "eddy current" braking system system that very accurately applies a brake to the ergometer
dynamic calibration continuous calibration during application of workload
power range at maximum rpm (maximum) 1000 W operational power range

Accuracy

workload accuracy below 100 W 3 W accuracy of the ergometer below 100 Watt load
workload accuracy from 100 to 500 W 3 % accuracy of the ergometer between 100 and 500 Watt
workload accuracy from 500 to 1000 W 5 % accuracy of the ergometer between 500 and 1000 Watt

Comfort

Q-factor 180 mm Q-factor
minimum leg length user 645 mm (25.4 inch) leg length to fit to pedals
minimum leg length user (incl. adjustable pedals) 602 mm (23.7 inch) leg length to fit to pedals when adjustable cranks are used (measured inseam)
allowed user weight 180 kg (396.8 lbs) maximum patient weight
handlebar adjustment angle 360 ° angle over which the handlebar can rotate
adjustability range seat 300 mm (11.8 inch) seat adjustment range

User Interface

English user interface User interface available in English language
Chinese user interface User interface available in Chinese language
Croatian user interface User interface available in croatian language
Czech user interface User interface available in Czech language
Danish user interface User interface available in Danishlanguage
Dutch user interface User interface available in Dutch language
Finnish user interface User interface available in Finnish language
French user interface User interface available in French language
German user interface User interface available in German language
Greek user interface User interface available in Greek language
Hungarian user interface User interface available in Hungarian language
Italian user interface User interface available in Italian language
Japanese user interface User interface available in language
Korean user interface User interface available in Korean language
Latvian user interface User interface available in Latvian language
Lithuanian user interface User interface available in Lithuanian language
Norwegian user interface User interface available in Norwegian language
Polish user interface User interface available in Polish language
Portugese user interface User interface available in Portugese language
Romanian user interface User interface available in romanian language
Russian user interface User interface available in Russian language
Spanish user interface User interface available in Spanish language
Swedish user interface User interface available in Swedish language
Turkish user interface User interface available in Turkish language
Ukrainian user interface User interface available in Ukrainian language
Readout RPM Readout the actual rpm on control unit
Readout Time Readout time on control unit
Readout Power Readout the actual power on control unit
Set Resistance Possibility to define a specific resistance for each test subject
screen size (diagonal) 17.78 cm (7 inch) diagonal size of the display
touchscreen operation by touch screen

Connectivity

Programmable Control Unit with 7" Touchscreen Can be controlled by the programmable control unit with Touchscreen
Lode interface protocol Supports communication according to the Lode ergometer protocol

Dimensions

product length (cm) 105 cm (41.3 inch) length of product in cm
product width (cm) 46 cm (18.1 inch) width of the product in cm
product height 114 cm (44.9 inch) height of product
product weight 65 kg (143.3 lbs) the weight of the product

Power requirements

V AC 100 - 240 V voltage in Volt
Phases 1 phases
Frequency 50/60 Hz frequency in Herz
Power consumption 160 W power consumption in Watt
Power cord length 250 cm (98.4 inch) length of powercord including plugs
Power cord IEC 60320 C13 with CEE 7/7 plug European power cord and connector standard supplied with product
Power cord NEMA NEMA power cord and connector

Standards & Safety

IEC 60601-1:2012 the product is IEC 60601-1 edition 3.1 compliant
ISO 13485:2016 compliant Lode fulfils ISO 13485:2016 requirements
ISO 9001:2015 compliant Lode fulfills ISO 9001: 2015 requirements

Certification

CE class Im according to MDD93/42/EEC CE certified
CE class of product with optional SpO2 IIa CE class of product with optional SpO2
CE class of product with optional BPM IIa CE class of product with optional Blood Pressure Measurement
CB according to IECEE CB CB certified

Environmental conditions

minimum operational temperature 14 °C minimum temperature at which the device will work within specification
maximum operational temperature 35 °C maximum temperature at which the device will work within specification
minimum operational air pressure 80 kPa minimum airpressure as from which the product will be operating within specification
maximum operational air pressure 106 kPa maximum air pressure as from which the product will be operating within specification
minimum operational non-condensing humidity 30 % minimum non-condensing humidity at which the product will operate within specification
maximum operational non-condensing humidity 90 % maximum non-condensing humidity at which the product will operate within specification
minimum storage & transport temperature -20 °C minimum temperature the product may be stored and transported at
maximum storage & transport temperature 60 °C maximum temperature the product may be stored or transported at
minimum air pressure storage & transport 50 kPa minimum air pressure the product may be stored or transported at
maximum storage & transport air pressure 106 kPa maximum air pressure the product may be stored and transported at
min. humidity storage & transport 10 % minimum non-condensing humidity that the product can be stored or transport at
max. humidity storage & transport 95 % max. non-condensing humidity that the product can be stored or transported at
Towards an individualized protocol for workload increments in cardiopulmonary exercise testing in children and adolescents with cystic fibrosis.
Exercise capacity in children with isolated congenital complete atrioventricularblock: does pacing make a difference?
Validity of the oxygen uptake efficiency slope in children with cystic fibrosis and mild-to-moderate airflow obstruction.
Effects of Exercise Therapy on Cardiorespiratory Fitness in Schizophrenia Patients.
Near-infrared spectroscopy during exercise and recovery in children with juvenile Dermatomyositis.
Habitual physical activity in Dutch children and adolescents with haemophilia.
Supramaximal Verification of Peak Oxygen Uptake in Adolescents With Cystic Fibrosis
Respiratory Gas Exchange During Exercise in Children with Congenital Heart Disease: Methodology and Clinical Concepts.
The steep ramp test in healthy children and adolescents: reliability and validity.
Human critical power-oxygen uptake relationship at different pedaling frequencies
Speeding of V̇O2 kinetics with endurance training in old and young men is associated with improved matching of local O2 delivery to muscle O2 utilization
Effects of exercise intensity on lymphocyte apoptosis induced by oxidative stress in men
The Effect of Acute Exercise on Serum Brain-Derived Neurotrophic Factor Levels and Cognitive Function
Development of exercise-induces arm-leg blood pressure gradient and abnormal arterial compliance in patients with repaired coarctation of the aorta.
Time course and mechanisms of adaptations in cardiorespiratory fitness with endurance training in older and young men
Role of exercise intensities in oxidized low-density lipoprotein-mediated redox status of monocyte in men
Muscle deoxygenation to VO2 relationship differs in young subjects with varying τVO2
Influence of carvedilol on the benefits of physical training in patients with moderate chronic heart failure
The Steep Ramp Test in Dutch Caucasian Children and Adolescents: Age- and Sex- Related Normative Values
Estimating peak oxygen uptake in adolescents with cystic fibrosis
Evaluation of vital parameter response to load changes using an ergometer system in a group of healthy subjects
Relationship between salivary and serum testosterone levels in response to different exercise intensities
Vitamin C and E supplementation prevents some of the cellular adaptations to endurance-training in humans.

Simulators

Simulator of 7 inch display, V1.0.39

Manuals

960906 - Manual CARDIO with HUR SmartTouch Ergometer English

960906 - Manual CARDIO with HUR SmartTouch Ergometer Dutch

960906 - Manual CARDIO with HUR SmartTouch Ergometer German

Certificates

CE Certificate Stress Test and Force Measurement Devices

ISO 9001:2015 Certificate

CB certificate Corival IV

ISO 13485: 2016 Certificate

MDoC Lode HUR Smarttouch devices

Dimension pictures

960900 Corival dimensions

ECDesign uploads of Lode-HUR SmartTouch products

Frequently asked questions

In what range are the handlebars of the Corival and Excalibur adjustable?

The Corival handlebar is adjustable within 0-360 degrees.
The Excalibur Sport’s handlebar is adjustable in both vertical (465- 855 mm) and horizontal (229- 600 mm) direction.

Is it possibe to estimate the travelled distance?

This is possible for all ergometers from 2004 on. Since 2009 it is possible to create yourn own calculation by using the adjustable resistance. Note: both pedalling speed and workload are taken into account by estimating the travelled distance.

Is it possible to put another saddle on the ergometer?

Yes, you can use most commercial available saddles. For the Excalibur an easy saddle exchange option is available. Please contact your service coordinator

Is it possible to control the Lode ergometers and treadmills with external CPET equipment?

Yes, you can find interface sheets for most common devices on the website at the “interfacing” tab of the product. If your CPET device is not present you can ask us to support you. In most cases we can quickly provide you with a solution.

What is heart rate controlled cycling / protocol?

During heartrate controlled cycling or running, you can determine a maximum heartrate limit. When this limit is reached, the ergometer/treadmill will adjust the workload/speed so the heartrate will stay more or less stable. You can perform a HR controlled test with the standard controller. You can program HR controlled protocols with the controller of the Valiant, Corival, Angio and Excalibur (more heartrate limits in one protocol (per step)), and the LEM (multi control) software module.

Is it possible to turn the display around so it is facing the physician?

Yes, before purchasing, you can order or it can be changed by a service engineer.

Is the SpO2 option compatible with LCRM?

Yes the SpO2 results are visible during the rehab session.

What is the Q factor of the Lode ergometers?

The Q factor of a bicycle ergometer is the distance from crank to crank. For the Excalibur the Q factor is simular to a racing bike meaning 147mm (+/- 3 mm).
The Q factor of the other ergometers is a little bit bigger (like a city bike), for the Corival this is 180 mm.

Is Lode recommending special disinfection procedures for the Lode products due to COVID-19?

Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!

Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.