Productafbeelding Blood Pressure with ECG trigger for bicycle ergometer

Blood Pressure with ECG trigger for bicycle ergometer

Part number: 945828
To Specifications

Highlight

Easy to operate

For Lode products this means:
– easy to connect
– easy to move around
– easy user interface

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Compatible with ECG and pulmonary devices

The treadmill can be controlled by all external stress test ECG and ergospirometry devices through the RS232 or USB port. This is possible because besides the programmed Lode protocol, all known communication protocols are programmed as well.

Feature

Versatile Interfacing

Various interface protocols guarantee perfect communication with all commonly known stress ECG and spirometry equipment

Original Accessory

Accessory designed and manufactured according to the Lode company quality standards

  • Specifications
  • Support
  • Accuracy
  • Connectivity

Accuracy

Accuracy BPM <300 mmHg 3 mmHgAccuracy of the BPM module between 0-300 mmHg
Minimum systolic measurement50 mmHgMinimum BPM Measurement Range
Maximum systolic measurement250 mmHgMaximum BPM Measurement Range
Minimum diastolic measurement20 mmHgMinimum BPM Measurement Range
Maximum diastolic measurement150 mmHgMaximum BPM Measurement Range

Connectivity

TTL input3-5 VTTL input required for BPM
Pulse length45 - 95 msPulse length required for BPM
Maximum delay between RS-peak and pulse40 msRequired for BPM
Variances in delay time (jitter)<5 msRequired for BPM

Manuals

M945828 - manual Blood Pressure Measurement for ergometer English

M945828 - manual Blood Pressure Measurement for ergometer Dutch

M945828 - manual Blood Pressure Measurement for ergometer Bulgarian

Certificates

Mdoc_MDR

Frequently asked questions

How do I clean the BPM Microphone?

The K-sound Microphone can be cleaned using a mild disinfectant wipe (e.g. Sani-Cloth®) and letting the microphone line dry.

How does the BPM option handle extreme situations like atrial or ventricular fibrillation, arrhythmias, pacemakers, etc.

Presence of atrial or ventricular fibrillation, arrhythmias, pacemakers, etc. may interfere with the normal functionality of the BP monitor.

Specifications Blood Pressure Measurement Measurement: Auscultatory, using R-wave gating and k-sound analysis, during all static and active phases of stress testing. Systolic pressures correlate to a K-1 Korotkoff sound. Diastolic pressures correlate to K-5 Korotkoff sound. The device is designed to function in the presence of a normal ECG sinus rhythm. There are some physical conditions (i.e. Bundle Branch Block, Arrhythmias, Arial Fibrillation, Ventricular Fibrillation, Pacemakers, etc.) that may limit the ability of BP Monitor to obtain an accurate reading.

Notes on Blood Pressure Data Any blood pressure reading can be affected by the measurement site, the position of the patient, exercise, or the patient’s physiologic condition. Environmental or operational factors which can affect the performance of the device and/or its blood pressure reading are pacemakers and common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy, pre-eclampsia, renal diseases, patient motion, trembling, and shivering.

Is Lode recommending special disinfection procedures for the Lode products due to COVID-19?

Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!

Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.

Is LCRM compatible with automatic BP measurement devices?

When the automatic Blood Pressure option is available on the Lode ergometer, this module is compatible with LCRM. You can program the blood pressure interval in the exercise protocols.