Introducing the Angio rehab with static wall fixation. Within this framework, the Angio rehab system is affixed securely to the wall, complete with integrated handgrips. Serving as an ergometric unit, the Angio rehab system facilitates both arm ergometry. Operating autonomously from pedalling speed, it spans the power range of 7 to 1000 watts. The Angio rehabilitation model is furnished with a 7″ touch screen control unit as a standard feature. Leveraging the embedded network module, seamless integration of the ergometer with Lode’s Cardiac Rehab Manager Software, Lode Rehab Manager, or the Lode Ergometry Manager is achievable.
Angio Rehab with static wall fixation
User friendly interface
The Angio rehab package includes an 7″ touch screen control unit, meticulously designed to elevate the user experience. Moreover, its integrated network module harmoniously merges with Lode’s specialized software, encompassing the Lode Cardiac Rehab Manager, Lode Rehab Manager, and the Lode Ergometry Manager.
Seamless Integration with LEM and LCRM
The effortless integration of the Angio Rehab system with the Lode Ergometry Manager (LEM) software creates a powerful collaboration aimed at enhancing patient-centred rehabilitation. This seamless connection facilitates the smooth transfer of exercise data from Angio Rehab sessions to LEM’s intuitive interface. Healthcare professionals can then monitor real-time exercise performance, capturing essential metrics such as pedal speed, workload, and heart rate. LEM’s dynamic platform simplifies the creation of personalized exercise profiles, nurturing customized rehabilitation regimens that align with each individual’s goals.
By combining the Angio Rehab system with the Lode Cardiac Rehab Manager (LCRM) software, a approach to cardiac rehabilitation management emerges. One of the biggest advantages of the use of L(C)RM is to be able to facilitate group training. With L(C)RM you are able to train with up to 16 patients at the same time. This fluid integration facilitates the exchange of exercise data and patient insights between the Angio Rehab system and LCRM, establishing a centralized hub for patient care. As patients engage in rehabilitation sessions using the Angio Rehab system, LCRM efficiently captures and organizes exercise data, enabling comprehensive monitoring of progress, performance and continues ECG data. This data-driven strategy empowers medical experts to design tailored cardiac rehabilitation plans that seamlessly adapt to individual needs and evolve alongside patients’ progress.
Why the Angio rehab with static wall fixation?
Reliable and reproducible stress tests
The experience of professionals who calibrate many ergometers shows that the Lode ergometers are the most reliable across the complete workload and rpm range and still within specifications even after many years of intensive use.
Easy to operate
For Lode products this means:
- Easy to connect
- Easy to move around
- Easy user interface
Additional features with PCU
Besides the possibility to program 24 protocols easily, this control unit offers the following features:
- Better monitoring because of the additional and larger display.
- A perfect combination with BPM.
- Possibility to measure SpO2.
High standards
Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.
Product features
Accurate over a long period of time
The Lode ergometers are supplied with an electro-magnetic braking mechanism of Lanooy (eddy current). The biggest advantage of this braking system compared to a friction braking system is the absolute accuracy and the accuracy over time. Moreover, friction braking systems have more wearing parts.
Extreme low start-up load
The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.
Small adjustment steps
The workload of the Lode ergometers is adjustable in steps of only 1 watt. Depending on your wishes, the test operator or the test subject can adjust the workload. The steps of 1 watt are possible in the manual mode as well as within protocols.
Versatile Interfacing
Various interface protocols guarantee perfect communication with all commonly known stress ECG and spirometry equipment
RS232 connectivity
RS232 ports enable connectivity to most ECG and ergospirometry devices as well as PC’s.
Related products
Unleashing advanced features
The Angio Rehab with static wall fixation introduces a range of customizable enhancements designed to cater to diverse clinical needs. The inclusion of the program function provides medical professionals with rapid access to exercise data, choosing from many protocols, promoting effective monitoring and analysis throughout rehabilitation sessions. Furthermore, expanded capabilities like SpO2 and heart rate monitoring enrich the Angio Rehab’s capabilities, facilitating a comprehensive assessment of patients’ physiological responses. These additional options not only enhance the precision of exercise evaluation and added safety by monitoring SpO2 and HR, but also streamline the workflow for healthcare providers, ensuring a personalized and efficient rehabilitation experience that aligns with the unique requirements of each patient.
Advantages of static wall fixation
Steadiness: The static wall fixation eliminates unwarranted vibrations and movements that could compromise data accuracy..
Efficient Space Utilization: Implementing fixed wall fixation maximizes the utilization of floor space, a particularly beneficial aspect for clinics with spatial constraints.
Other options for wall fixation
In addition to the static wall fixation, we also provide an electrically adjustable wall fixation solution and the Angio with an automatic stand. Explore these products to see how their height adjustability can offer the optimal solution for your patients.
- Specifications
- Science
- Support
- Marketing
Workload
| workload range fixed torque | 0,1 - 70 Nm | Workload range in fixed torque mode |
|---|---|---|
| minimum load | 7 W | the minimum load the ergometer can provide |
| maximum peak load | 1000 W | the maximum load the ergometer can provide for a short period of time |
| minimum load increments | 1 W | the smallest steps with which the load can be added |
| maximum continuous load | 750 W | the maximum power the ergometer can deliver continuous |
| hyperbolic workload control | control of workload in hyperbolic way | |
| linear workload control | control ergometer in a linear way | |
| fixed torque workload control | control ergometer in a fixed torque way | |
| maximum rpm independent constant load | 150 rpm | rpm as to which constant load can be applied |
| minimum rpm independent constant load | 30 rpm | rpm as from which constant load can be applied |
| optional heart rate controlled workload | control the device optionally through a set heartrate | |
| electromagnetic "eddy current" braking system | system that very accurately applies a brake to the ergometer |
Accuracy
| workload accuracy from 7 to 100 W | 3 W | accuracy of the ergometer between 7 and 100 Watt |
|---|---|---|
| workload accuracy from 100 to 500 W | 3 % | accuracy of the ergometer between 100 and 500 Watt |
| workload accuracy from 500 to 1000 W | 5 % | accuracy of the ergometer between 500 and 1000 Watt |
User Interface
| English user interface | User interface available in English language | |
|---|---|---|
| Chinese user interface | User interface available in Chinese language | |
| Croatian user interface | User interface available in croatian language | |
| Czech user interface | User interface available in Czech language | |
| Danish user interface | User interface available in Danishlanguage | |
| Dutch user interface | User interface available in Dutch language | |
| Finnish user interface | User interface available in Finnish language | |
| French user interface | User interface available in French language | |
| German user interface | User interface available in German language | |
| Greek user interface | User interface available in Greek language | |
| Hungarian user interface | User interface available in Hungarian language | |
| Italian user interface | User interface available in Italian language | |
| Japanese user interface | User interface available in language | |
| Korean user interface | User interface available in Korean language | |
| Latvian user interface | User interface available in Latvian language | |
| Lithuanian user interface | User interface available in Lithuanian language | |
| Norwegian user interface | User interface available in Norwegian language | |
| Polish user interface | User interface available in Polish language | |
| Portugese user interface | User interface available in Portugese language | |
| Romanian user interface | User interface available in romanian language | |
| Russian user interface | User interface available in Russian language | |
| Spanish user interface | User interface available in Spanish language | |
| Swedish user interface | User interface available in Swedish language | |
| Turkish user interface | User interface available in Turkish language | |
| Ukrainian user interface | User interface available in Ukrainian language | |
| Readout Distance | Readout the distance on control unit | |
| Readout RPM | Readout the actual rpm on control unit | |
| Readout Heartrate | Readout the actual heartarte on control unit | |
| Readout target HR | Readout target heartarte on control unit (only possible with HR option) | |
| Readout Energy | Readout the energy on control unit | |
| Readout Torque | Readout torque on control unit | |
| Readout Time | Readout time on control unit | |
| Readout Power | Readout the actual power on control unit | |
| Set Display | Choosing parameters to be shown on the display during the stress test | |
| Set Resistance | Possibility to define a specific resistance for each test subject | |
| Set P-Slope | Possibility to set the load regulation resistance | |
| Set Mode | Possibility to define parameters to be adjusted during the stress test | |
| manual operation mode | Operate manually | |
| preset protocol operation mode | Operate via preset protocols | |
| external control unit | a control unit is connected with a cable to the ergometer | |
| selfdesigned protocol operation mode | operate via selfdesigned protocols |
Dimensions
| product length (cm) | 54 cm (21.3 inch) | length of product in cm |
|---|---|---|
| product width (cm) | 68 cm (26.8 inch) | width of the product in cm |
| product height | 73 cm (28.7 inch) | height of product |
| product weight | 55 kg (121.3 lbs) | the weight of the product |
Power requirements
| V AC | 100 - 240 V | voltage in Volt |
|---|---|---|
| Phases | 1 | phases |
| Frequency | 50/60 Hz | frequency in Herz |
| Power consumption | 160 W | power consumption in Watt |
| Power cord IEC 60320 C13 with CEE 7/7 plug | European power cord and connector standard supplied with product | |
| Power cord NEMA | NEMA power cord and connector | |
| 100 - 240 V 50/60 Hz (160 Watt) | operational power |
Standards & Safety
| IEC 60601-1:2012 | the product is IEC 60601-1 edition 3.1 compliant | |
|---|---|---|
| ISO 13485:2016 compliant | Lode fulfils ISO 13485:2016 requirements | |
| ISO 9001:2015 compliant | Lode fulfills ISO 9001: 2015 requirements |
Certification
| CE class Im according to MDD93/42/EEC | CE certified | |
|---|---|---|
| CE class of product with optional SpO2 | IIa | CE class of product with optional SpO2 |
| CE class of product with optional BPM | IIa | CE class of product with optional Blood Pressure Measurement |
| CB according to IECEE CB | CB certified |
Environmental conditions
| minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification |
|---|---|---|
| maximum operational temperature | 40 °C | maximum temperature at which the device will work within specification |
| minimum operational air pressure | 80 kPa | minimum airpressure as from which the product will be operating within specification |
| maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification |
| minimum operational non-condensing humidity | 30 % | minimum non-condensing humidity at which the product will operate within specification |
| maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification |
| minimum storage & transport temperature | -20 °C | minimum temperature the product may be stored and transported at |
| maximum storage & transport temperature | 60 °C | maximum temperature the product may be stored or transported at |
| minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at |
| maximum storage & transport air pressure | 106 kPa | maximum air pressure the product may be stored and transported at |
| min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at |
| max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at |
Simulators
Simulator of 7 inch display, V1.0.39
Manuals
M967922 - Manual Angio rehab static wall fixation
Date of publication: February 24, 2017
M967922 - Manual Angio rehab static wall fixation Dutch
Date of publication: February 24, 2017
M967922 - Manual Angio rehab static wall fixation German
Date of publication: February 24, 2017
Certificates
CE Certificate Stress Test and Force Measurement Devices
ISO 9001:2015 Certificate
UL CSA Angio series certificate
Manufacturers Declaration of Conformity 27 Lode
IEC 60601-1:2005 – ed. 3 + C1 + C2 (cycle ergometers) certificate
FDA Registration certificate
ISO 13485: 2016 Certificate
IEC 60601-1:2005 Angio Ergometers
Dimension pictures
Dimensions of the Angio (3.5 inch screen)
Frequently asked questions
Is it possible to request RPM and Load data through the RS232 port while cycling in Manual mode.
Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode.
The load will only be returned when the pedalling speed is 30 RPM or more. For technical details see the Lode RS232 protocol
Can I use a RS232 to USB converter to connect an ergometer?
Yes you can. Make sure the chipset used in the converter is from FTDI to have good data acquisition.
Not sure what this means? Contact us and we will help you to get the right converter.
Can I loop Lode rehab products easily?
Yes! It is very easy to create a comfortable rehab setting with Lode rehab products by looping the ergometers:
The first Lode rehab ergometer can be connected to the PC with LCRM with a Lode proprietary network to PC cable (#930930).
The second product up till the last product can be connected to the previous one, a bus network configuration.
The last product always needs a termination plug to avoid interference and loss of data. All Lode rehab products come standard with such a termination plug.
Benefits
– Flawless data connection
– High bandwidth
– No interference of COM ports
– Looping
– Full access of all data in the product to LCRM
Is Lode recommending special disinfection procedures for the Lode products due to COVID-19?
Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!
Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.