Productafbeelding Angio Rehab – with automatic stand

Angio Rehab - with automatic stand

Discover the revolutionary Angio Rehab with Automatic Stand, an innovative solution that redefines the field of medical rehabilitation. Seamlessly integrating arm and leg ergometry for an enhanced rehabilitation experience.

Part number: 967924
To Specifications

Angio Rehab with automatic stand

Introducing the Angio Rehab with automatic stand: a cutting-edge solution tailored to elevate the field of medical rehabilitation. With its innovative design and versatile capabilities, the Angio Rehab stands as a pinnacle of advanced ergometry technology. Engineered to address the diverse needs of medical professionals and patients alike, this remarkable system seamlessly integrates arm and leg ergometry, helping in a new era of comprehensive rehabilitation practices. Through its automatic stand, customizable exercise settings, the Angio Rehab redefines rehabilitation possibilities, empowering healthcare providers to deliver targeted and effective care.

The automatic stand for the Angio ergometer includes a remarkable feature – the ability to adjust its height within a generous range of 140 cm. this feature ensures that all patients can achieve an optimal position for arm ergometry. Additionally, this adaptability empowers patients to seamlessly transition and utilize the device for leg ergometry as well. This advancement simplifies the process of relocating your arm ergometry setup to different rooms, as the ergometer can stand independently with the option of being attached to a wall.

By incorporating the automatic stand, the Angio transforms into an all-inclusive ergometric unit suitable for both arm and leg ergometry. This solution, complete with handgrips, is the standard. Due to the eddy current braking system, the Angio can be operated within a wattage range of 7 to 1000 watts, regardless of pedalling speed, which can range between 30 and 150 RPM (revolutions per minute). Additionally, it is also possible to train linearly, where the wattage increases with higher RPM, which may feel more intuitive for some rehabilitation patients.

Why the Angio rehab with automatic stand?

Reliable and reproducible stress tests

The experience of professionals who calibrate many ergometers shows that the Lode ergometers are the most reliable across the complete workload and rpm range and still within specifications even after many years of intensive use.

Additional features with PCU

Besides the possibility to program 24 protocols easily, this control unit offers the following features:

  • Better monitoring because of the additional and larger display.
  • A perfect combination with BPM.
  • Possibility to measure SpO2.

Easy to operate

For Lode products this means:

  • Easy to connect
  • Easy to move around
  • Easy user interface

High standards

Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.

Multifunctional

The ergometer can be used for both arm and leg ergometry.

Product features

Small adjustment steps

The workload of the Lode ergometers is adjustable in steps of only 1 watt. Depending on your wishes, the test operator or the test subject can adjust the workload. The steps of 1 watt are possible in the manual mode as well as within protocols.

Extreme low start-up load

The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.

Accurate over a long period of time

The Lode ergometers are supplied with an electro-magnetic braking mechanism of Lanooy (eddy current). The biggest advantage of this braking system compared to a friction braking system is the absolute accuracy and the accuracy over time. Moreover, friction braking systems have more wearing parts.

LEM compatible

This product can be used with Lode Ergometry Manager (LEM) software to manage data and to apply specific protocols when a Communication card is present

LCRM compatible

This product can be used with Lode Cardiac Rehabilitation Manager software (LCRM).

Customer specific display setting

Display settings are adjustable according to your specific requirements: each individual has its specific wishes about the parameters to be displayed. This can easily be adjusted with the Lode ergometers.

Versatile Interfacing

Various interface protocols guarantee perfect communication with all commonly known stress ECG and spirometry equipment.

Related products

967923 - Angio Rehab - with electrical adjustable wall fixation

Angio Rehab – with electrical adjustable wall fixation

967925 Angio rehab

Angio Rehab – with fixation set for instrument rail

967922 - Angio Rehab - with static wall fixation

Angio Rehab – with static wall fixation

Lode-LCRM-video

Lode Cardiac Rehab Manager

Safety and options

Unlocking advanced capabilities

The Angio Rehab with automatic stand offers a range of customizable enhancements to cater to diverse clinical needs. The Angio Rehab can be enriched with additional features like SpO2and heart rate monitoring capabilities. These additional options not only enhance the accuracy of exercise assessment but also streamline the workflow for healthcare providers. This guarantees a personalized rehabilitation experience that caters to the unique requirements of each patient.

Advantages of the automatic stand

The automatic stand brings forth a range of advantages that enhance the experience of arm ergometry. By firmly securing the ergometer to the wall using the provided components, users can establish unparalleled stability during rigorous and demanding sessions. This not only amplifies safety but also facilitates consistent and precise data collection. For those pursuing adaptable configurations, the optional stabilisation leg emerges as a great alternative, offering additional support without necessitating wall attachment. This flexibility ensures seamless integration of the ergometer into diverse settings, catering to the multifaceted requirements of users. Additionally, the Angio’s effortless height adjustment further amplifies its versatility, enabling its utilization for both arm and leg ergometry and finding the optimal position for efficient and comfortable pedalling. Offering the Angio significantly contributes to providing a training option for a broader group of patients. This includes individuals with lower body impairments, such as those in a wheelchair, but it can also be used for individuals who need to specifically train their upper body.

  • Specifications
  • Science
  • Support
  • Marketing
  • Workload
  • Accuracy
  • Comfort
  • User Interface
  • Dimensions
  • Power requirements
  • Standards & Safety
  • Certification
  • Environmental conditions

Workload

workload range fixed torque 0,1 - 70 Nm Workload range in fixed torque mode
minimum load 7 W the minimum load the ergometer can provide
maximum peak load 1000 W the maximum load the ergometer can provide for a short period of time
minimum load increments 1 W the smallest steps with which the load can be added
maximum continuous load 750 W the maximum power the ergometer can deliver continuous
hyperbolic workload control control of workload in hyperbolic way
maximum rpm independent constant load 150 rpm rpm as to which constant load can be applied
minimum rpm independent constant load 30 rpm rpm as from which constant load can be applied
electromagnetic "eddy current" braking system system that very accurately applies a brake to the ergometer
dynamic calibration continuous calibration during application of workload

Accuracy

workload accuracy from 7 to 100 W 3 W accuracy of the ergometer between 7 and 100 Watt
workload accuracy from 100 to 500 W 3 % accuracy of the ergometer between 100 and 500 Watt
workload accuracy from 500 to 1000 W 5 % accuracy of the ergometer between 500 and 1000 Watt

Comfort

adjustability range height 1400 mm adjustability range height

User Interface

English user interface User interface available in English language
Chinese user interface User interface available in Chinese language
Croatian user interface User interface available in croatian language
Czech user interface User interface available in Czech language
Danish user interface User interface available in Danishlanguage
Dutch user interface User interface available in Dutch language
Finnish user interface User interface available in Finnish language
French user interface User interface available in French language
German user interface User interface available in German language
Greek user interface User interface available in Greek language
Hungarian user interface User interface available in Hungarian language
Italian user interface User interface available in Italian language
Japanese user interface User interface available in language
Korean user interface User interface available in Korean language
Latvian user interface User interface available in Latvian language
Lithuanian user interface User interface available in Lithuanian language
Norwegian user interface User interface available in Norwegian language
Polish user interface User interface available in Polish language
Portugese user interface User interface available in Portugese language
Romanian user interface User interface available in romanian language
Russian user interface User interface available in Russian language
Spanish user interface User interface available in Spanish language
Swedish user interface User interface available in Swedish language
Turkish user interface User interface available in Turkish language
Ukrainian user interface User interface available in Ukrainian language
Readout Distance Readout the distance on control unit
Readout RPM Readout the actual rpm on control unit
Readout Heartrate Readout the actual heartarte on control unit
Readout target HR Readout target heartarte on control unit (only possible with HR option)
Readout Energy Readout the energy on control unit
Readout Torque Readout torque on control unit
Readout Time Readout time on control unit
Readout Power Readout the actual power on control unit
Set Display Choosing parameters to be shown on the display during the stress test
Set Resistance Possibility to define a specific resistance for each test subject
Set P-Slope Possibility to set the load regulation resistance
Set Mode Possibility to define parameters to be adjusted during the stress test
manual operation mode Operate manually
preset protocol operation mode Operate via preset protocols
analog operation mode operate analog
terminal operation mode operate with an external device
external control unit a control unit is connected with a cable to the ergometer
selfdesigned protocol operation mode operate via selfdesigned protocols

Dimensions

product length (cm) 84 cm (33.1 inch) length of product in cm
product width (cm) 82 cm (32.3 inch) width of the product in cm
product height 223 cm (87.8 inch) height of product
product weight 95 kg (209.4 lbs) the weight of the product
width between stand 67 cm room between stand for chair or wheelchair

Power requirements

V AC 100 - 240 V voltage in Volt
Phases 1 phases
Frequency 50/60 Hz frequency in Herz
Power consumption 250 W power consumption in Watt
Power cord IEC 60320 C13 with CEE 7/7 plug European power cord and connector standard supplied with product
Power cord NEMA NEMA power cord and connector

Standards & Safety

IEC 60601-1:2012 the product is IEC 60601-1 edition 3.1 compliant
ISO 13485:2016 compliant Lode fulfils ISO 13485:2016 requirements
ISO 9001:2015 compliant Lode fulfills ISO 9001: 2015 requirements

Certification

CE class Im according to MDD93/42/EEC CE certified
CE class of product with optional SpO2 IIa CE class of product with optional SpO2
CE class of product with optional BPM IIa CE class of product with optional Blood Pressure Measurement
CB according to IECEE CB CB certified

Environmental conditions

minimum operational temperature 14 °C minimum temperature at which the device will work within specification
maximum operational temperature 35 °C maximum temperature at which the device will work within specification
minimum operational air pressure 80 kPa minimum airpressure as from which the product will be operating within specification
maximum operational air pressure 106 kPa maximum air pressure as from which the product will be operating within specification
minimum operational non-condensing humidity 30 % minimum non-condensing humidity at which the product will operate within specification
maximum operational non-condensing humidity 90 % maximum non-condensing humidity at which the product will operate within specification
minimum storage & transport temperature -20 °C minimum temperature the product may be stored and transported at
maximum storage & transport temperature 60 °C maximum temperature the product may be stored or transported at
minimum air pressure storage & transport 50 kPa minimum air pressure the product may be stored or transported at
maximum storage & transport air pressure 106 kPa maximum air pressure the product may be stored and transported at
min. humidity storage & transport 10 % minimum non-condensing humidity that the product can be stored or transport at
max. humidity storage & transport 95 % max. non-condensing humidity that the product can be stored or transported at
The Influence of Step and Ramp Type Protocols on the Attainment of Peak Physiological Responses During Arm Crank Ergometry
Left ventricular mechanical limitations to stroke volume in healthy humans during incremental exercise
The influence of crank rate on peak oxygen consumption during arm crank ergometry
Physical Fitness of Lower Limb Amputees
The influence of crank configuration on muscle activity and torque production during arm crank Ergometry
Influence of training status and exercise modality on pulmonary O2 uptake kinetics in pre-pubertal girls
Effects of Arm-Cranking Exercise in Cutaneous Microcirculation in Older, Sedentary People
Comparison of Lower- vs. Upper-Body Cooling During Arm Exercise in Hot Conditions
Studying the cutaneous microcirculatory response during upper-limb exercise in healthy, older, sedentary people
Subjective Measures of Exercise Intensity to Gauge Substrate Partitioning in Persons With Paraplegia
Arm exercise testing predicts clinical outcome
Experimental Protocol of a Three-minute, All-out Arm Crank Exercise Test in Spinal-cord Injured and Able-bodied Individuals (video article)
Effects of cardiac rehabilitation and exercise training programs on depression in patients after major coronary events
The Relation of Arm Exercise Peak Heart Rate to Stress Test Results and Outcome
A prognostic scoring system for arm exercise stress testing
Validity and Reliability of Skill-Related Fitness Tests for Wheelchair-Using Youth With Spina Bifida.
Arm exercise stress testing: diagnostic options in stable coronary artery disease

LCRM Demo Software

Installation Instruction LCRM Demosoftware

950902 LCRM 3.4.2 demo software

Simulators

Simulator of 7 inch display, V1.0.39

Manuals

M967924 - Manual Angio rehab with automatic stand English

M967924 - Manual Angio rehab with automatic stand German

M967924 - Manual Angio rehab with automatic stand Dutch

Certificates

CE Certificate Stress Test and Force Measurement Devices

ISO 9001:2015 Certificate

UL CSA Angio series certificate

Manufacturers Declaration of Conformity 27 Lode

IEC 60601-1:2005 – ed. 3 + C1 + C2 (cycle ergometers) certificate

FDA Registration certificate

ISO 13485: 2016 Certificate

IEC 60601-1:2005 Angio Ergometers

LEM Demo Software

955900 LEM 10.15.0 Demo software

Dimension pictures

Dimensions of the Angio (3.5 inch screen)

Frequently asked questions

Is it possible to request RPM and Load data through the RS232 port while cycling in Manual mode.

Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode.
The load will only be returned when the pedalling speed is 30 RPM or more. For technical details see the Lode RS232 protocol

Can I use a RS232 to USB converter to connect an ergometer?

Yes you can. Make sure the chipset used in the converter is from FTDI to have good data acquisition.
Not sure what this means? Contact us and we will help you to get the right converter.

Can I loop Lode rehab products easily?

Yes! It is very easy to create a comfortable rehab setting with Lode rehab products by looping the ergometers:

The first Lode rehab ergometer can be connected to the PC with LCRM with a Lode proprietary network to PC cable (#930930).
The second product up till the last product can be connected to the previous one, a bus network configuration.

The last product always needs a termination plug to avoid interference and loss of data. All Lode rehab products come standard with such a termination plug.

Benefits
– Flawless data connection
– High bandwidth
– No interference of COM ports
– Looping
– Full access of all data in the product to LCRM

Is Lode recommending special disinfection procedures for the Lode products due to COVID-19?

Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!

Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.

Will my existing Lode streamers and ergometers still be compatible when I upgrade the LCRM software to a newer version?

Yes you can upgrade to a newer LCRM version without any influence on the total LCRM installation, The Lode Streamers, ergometers and treadmills will work as usual.

Is it possible to lower the workload in case of a sudden SpO2 drop?

SpO2 can be used to control the load of the ergometer. In the tab “SpO2 ” you can choose to use SpO2 for automatic load adjustment and you can edit the settings (see manual LCRM 950902)

Is it possible to use the PWC protocol with LCRM?

A Physical Work Capacity (PWC) Protocol can be programmed for the bicycle ergometers. During a PWC protocol the workload will increase every 2 seconds with 1 watt untill the set heart rate is reached. The Workload belonging to the target heart rate is the PWC result which is dependent on the physical condition of the patient.