Angio CPET with static wall fixation
Streamlined wall fixation for enhanced ergometry precision
In this configuration, the Angio CPET with static wall fixation system is securely affixed to the wall, accompanied by standard handgrips for optimal grip. Its sleek and compact design renders it suitable for an array of stress tests, particularly in scenarios where conventional ergometry setups prove impractical. Remarkably, the Angio functions independently of pedalling speed, spanning a wattage range of 7 to 1000 watts.
Enhancing its capabilities, the Angio CPET comes equipped with an integrated communication module, facilitating seamless control compatibility with prevalent stress ECG and pulmonary devices worldwide. Vital performance metrics including workload, revolutions per minute (rpm), and time are effortlessly accessible through the connected CPET system.
To see which cardiopulmonary stress test equipment the Angio CPET is compatible with, go to the specifications section and click on the “Interfacing” tab. There, you’ll find the full list of supported systems.
Angio CPET with static wall fixation
Connectivity options
Delve into your analyses with ease as the 3.5″ color display provides real-time access to crucial metrics such as workload, revolutions per minute (rpm), and time. This data readout ensures a streamlined and comprehensive evaluation process through the CPET software.
Enhancing display options with 7-inch control unit or programmable control unit
For those in search of extra functionalities, we provide a range of display alternatives. Select the 7-inch control unit, to control the Angio and make it possible to use it as a standalone device. A larger screen for comprehensive data visualization. Taking personalization to the next level, the Programmable Control Unit (PCU) offers an advanced level of flexibility. Unlike the standard the 3,5 display, the CU and PCU empowers medical practitioners to finely adjust display settings and parameters according to precise preferences. This choice provides a high degree of control, allowing users to define and organize specific metrics, making it perfect for those who require utmost adaptability in data presentation. With the PCU, you can set targets, utilize various pre-programmed protocols, and even incorporate up to 50 custom protocols. You have the flexibility to create personalized protocols, incorporating different ramp, interval, and heart rate-based protocols, tailored to your specific needs.
Why the Angio cpet with static wall fixation?
Reliable and reproducible stress tests
The experience of professionals who calibrate many ergometers shows that the Lode ergometers are the most reliable across the complete workload and rpm range and still within specifications even after many years of intensive use.
Additional features with PCU
Besides the possibility to program 24 protocols easily, this control unit offers the following features:
- Better monitoring because of the additional and larger display.
- A perfect combination with BPM.
- Possibility to measure SpO2.
Easy to operate
For Lode products this means:
- Easy to connect
- Easy to move around
- Easy user interface
High standards
Lode is a socially and environmentally responsible company. All Lode products are RoHS/WEEE compliant and Lode is ISO 9001:2015, and ISO 13485:2016 certified. All medical products comply to MDD 93/42/EEC, incl. IEC 60601-1.
Product features
Extreme low start-up load
The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.
Accurate over a long period of time
The Lode ergometers are supplied with an electro-magnetic braking mechanism of Lanooy (eddy current). The biggest advantage of this braking system compared to a friction braking system is the absolute accuracy and the accuracy over time. Moreover, friction braking systems have more wearing parts.
Small adjustment steps
The workload of the Lode ergometers is adjustable in steps of only 1 watt. Depending on your wishes, the test operator or the test subject can adjust the workload. The steps of 1 watt are possible in the manual mode as well as within protocols.
LCRM compatible
This product can be used with Lode Cardiac Rehabilitation Manager software (LCRM)
LEM compatible
This product can be used with Lode Ergometry Manager (LEM) software to manage data and to apply specific protocols when a Communication card is present
Customer specific display setting
Display settings are adjustable according to your specific requirements: each individual has its specific wishes about the parameters to be displayed. This can easily be adjusted with the Lode ergometers.
Versatile Interfacing
Various interface protocols guarantee perfect communication with all commonly known stress ECG and spirometry equipment
RS232 connectivity
RS232 ports enable connectivity to most ECG and ergospirometry devices as well as PC’s.
Related products
Angio CPET with static wall fixation possibilities
The Angio CPET with Static Wall Fixation embraces innovation by having Smart Heart Rate and SpO2 capabilities in combination with our Control Unit, revolutionizing cardiovascular assessments. This integration allows for real-time monitoring of heart rate and oxygen saturation levels, providing invaluable physiological insights during exercise tests.
The Angio CPET harmoniously syncs with established stress ECG and pulmonary devices, fostering an ecosystem of unified control. Medical professionals can effortlessly manage and monitor the device through their preferred CPET system, streamlining data acquisition and interpretation. The result is a seamless, integrated workflow that enhances precision, saves time, and empowers clinicians to optimize their workflow.
Advantages of wall fixation
Stability and Accuracy: Wall fixation eliminates unwanted vibrations and movement that can affect data accuracy during exercise tests. This stability ensures consistent and reliable measurements, crucial for accurate patient evaluation.
Optimal Space Utilization: Fixed wall fixation optimizes floor space, an advantage in clinics with limited room. The setup eliminates the need for bulky equipment, making the examination area more organized and accessible.
Other options for wall fixation
In addition to the static wall fixation, we also provide an electrically adjustable wall fixation solution and the Angio with an automatic stand. Explore these products to see how their height adjustability can offer the optimal solution for your patients.
- Specifications
- Science
- Support
- Interfacing
- Marketing
Workload
| Torque range | 1-70 Nm | Torque range for rpm independent workload control |
|---|---|---|
| minimum load | 7 W | the minimum load the ergometer can provide |
| maximum peak load | 1000 W | the maximum load the ergometer can provide for a short period of time |
| minimum load increments | 1 W | the smallest steps with which the load can be added |
| maximum continuous load | 750 W | the maximum power the ergometer can deliver continuous |
| hyperbolic workload control | control of workload in hyperbolic way | |
| maximum rpm independent constant load | 150 rpm | rpm as to which constant load can be applied |
| minimum rpm independent constant load | 30 rpm | rpm as from which constant load can be applied |
| optional heart rate controlled workload | control the device optionally through a set heartrate | |
| electromagnetic "eddy current" braking system | system that very accurately applies a brake to the ergometer | |
| dynamic calibration | continuous calibration during application of workload |
Accuracy
| workload accuracy from 7 to 100 W | 3 W | accuracy of the ergometer between 7 and 100 Watt |
|---|---|---|
| workload accuracy from 100 to 500 W | 3 % | accuracy of the ergometer between 100 and 500 Watt |
| workload accuracy from 500 to 1000 W | 5 % | accuracy of the ergometer between 500 and 1000 Watt |
User Interface
| English user interface | User interface available in English language | |
|---|---|---|
| Chinese user interface | User interface available in Chinese language | |
| Croatian user interface | User interface available in croatian language | |
| Czech user interface | User interface available in Czech language | |
| Danish user interface | User interface available in Danishlanguage | |
| Dutch user interface | User interface available in Dutch language | |
| Finnish user interface | User interface available in Finnish language | |
| French user interface | User interface available in French language | |
| German user interface | User interface available in German language | |
| Greek user interface | User interface available in Greek language | |
| Hungarian user interface | User interface available in Hungarian language | |
| Italian user interface | User interface available in Italian language | |
| Japanese user interface | User interface available in language | |
| Korean user interface | User interface available in Korean language | |
| Latvian user interface | User interface available in Latvian language | |
| Lithuanian user interface | User interface available in Lithuanian language | |
| Norwegian user interface | User interface available in Norwegian language | |
| Polish user interface | User interface available in Polish language | |
| Portugese user interface | User interface available in Portugese language | |
| Romanian user interface | User interface available in romanian language | |
| Russian user interface | User interface available in Russian language | |
| Spanish user interface | User interface available in Spanish language | |
| Swedish user interface | User interface available in Swedish language | |
| Turkish user interface | User interface available in Turkish language | |
| Ukrainian user interface | User interface available in Ukrainian language | |
| Readout Distance | Readout the distance on control unit | |
| Readout RPM | Readout the actual rpm on control unit | |
| Readout Heartrate | Readout the actual heartarte on control unit | |
| Readout target HR | Readout target heartarte on control unit (only possible with HR option) | |
| Readout Energy | Readout the energy on control unit | |
| Readout Torque | Readout torque on control unit | |
| Readout Time | Readout time on control unit | |
| Readout Power | Readout the actual power on control unit | |
| Set Display | Choosing parameters to be shown on the display during the stress test | |
| Set Resistance | Possibility to define a specific resistance for each test subject | |
| Set P-Slope | Possibility to set the load regulation resistance | |
| Set Mode | Possibility to define parameters to be adjusted during the stress test | |
| manual operation mode | Operate manually | |
| preset protocol operation mode | Operate via preset protocols | |
| terminal operation mode | operate with an external device | |
| external control unit | a control unit is connected with a cable to the ergometer | |
| selfdesigned protocol operation mode | operate via selfdesigned protocols |
Dimensions
| product length (cm) | 54 cm (21.3 inch) | length of product in cm |
|---|---|---|
| product width (cm) | 68 cm (26.8 inch) | width of the product in cm |
| product height | 73 cm (28.7 inch) | height of product |
| product weight | 55 kg (121.3 lbs) | the weight of the product |
Power requirements
| V AC | 100 - 240 V | voltage in Volt |
|---|---|---|
| Phases | 1 | phases |
| Frequency | 50/60 Hz | frequency in Herz |
| Power consumption | 160 W | power consumption in Watt |
| Power cord IEC 60320 C13 with CEE 7/7 plug | European power cord and connector standard supplied with product | |
| Power cord NEMA | NEMA power cord and connector |
Standards & Safety
| IEC 60601-1:2012 | the product is IEC 60601-1 edition 3.1 compliant | |
|---|---|---|
| ISO 13485:2016 compliant | Lode fulfils ISO 13485:2016 requirements | |
| ISO 9001:2015 compliant | Lode fulfills ISO 9001: 2015 requirements |
Certification
| CE class Im according to MDD93/42/EEC | CE certified | |
|---|---|---|
| CE class of product with optional SpO2 | IIa | CE class of product with optional SpO2 |
| CE class of product with optional BPM | IIa | CE class of product with optional Blood Pressure Measurement |
| CB according to IECEE CB | CB certified |
Environmental conditions
| minimum operational temperature | 14 °C | minimum temperature at which the device will work within specification |
|---|---|---|
| maximum operational temperature | 40 °C | maximum temperature at which the device will work within specification |
| minimum operational air pressure | 80 kPa | minimum airpressure as from which the product will be operating within specification |
| maximum operational air pressure | 106 kPa | maximum air pressure as from which the product will be operating within specification |
| minimum operational non-condensing humidity | 30 % | minimum non-condensing humidity at which the product will operate within specification |
| maximum operational non-condensing humidity | 90 % | maximum non-condensing humidity at which the product will operate within specification |
| minimum storage & transport temperature | -20 °C | minimum temperature the product may be stored and transported at |
| maximum storage & transport temperature | 60 °C | maximum temperature the product may be stored or transported at |
| minimum air pressure storage & transport | 50 kPa | minimum air pressure the product may be stored or transported at |
| maximum storage & transport air pressure | 106 kPa | maximum air pressure the product may be stored and transported at |
| min. humidity storage & transport | 10 % | minimum non-condensing humidity that the product can be stored or transport at |
| max. humidity storage & transport | 95 % | max. non-condensing humidity that the product can be stored or transported at |
Manuals
M967902 - Manual Angio cpet static wall fixation
Date of publication: February 24, 2017
M967902 - Manual Angio cpet static wall fixation _ Dutch
Date of publication: February 24, 2017
M967902 - Manual Angio cpet static wall fixation _ German
Date of publication: December 5, 2023
Certificates
CE Certificate Stress Test and Force Measurement Devices
ISO 9001:2015 Certificate
UL CSA Angio series certificate
Manufacturers Declaration of Conformity 27 Lode
IEC 60601-1:2005 – ed. 3 + C1 + C2 (cycle ergometers) certificate
FDA Registration certificate
ISO 13485: 2016 Certificate
IEC 60601-1:2005 Angio Ergometers
Dimension pictures
Dimensions of the Angio (3.5 inch screen)
Frequently asked questions
Is it possible to request RPM and Load data through the RS232 port while cycling in Manual mode.
Yes you can request the actual pedalling speed and power when you are cycling in Manual, Analogue or Terminal mode.
The load will only be returned when the pedalling speed is 30 RPM or more. For technical details see the Lode RS232 protocol
How do I know how to interface my ECG or ergospirometry device to a Lode product?
In the SERVICE tab of every product, you find all available interfacing options.
You can download a short instruction on how to choose the right settings on your ergometer or treadmill and the ECG or ergospirometry device.
Can I use a RS232 to USB converter to connect an ergometer?
Yes you can. Make sure the chipset used in the converter is from FTDI to have good data acquisition.
Not sure what this means? Contact us and we will help you to get the right converter.
Is Lode recommending special disinfection procedures for the Lode products due to COVID-19?
Yes, Due to the fact that the scientific research on the spread of Covid-19 is not yet conclusive Lode recommends to disinfect and clean all Lode products and their accessories (cuffs, heart rate belts, SpO2 sensors, handgrips/rails, touchscreens etc) that are in contact with the patient and or the medical personnel with a standard disinfectant as used in the hospital before and after every patient, with attention and care!
Since these agents are sometimes aggressive it might be advisable to check the effect on sensitive surfaces, like cushioning on non-visible areas. Lode will not take responsibility for discoloration due to these agents.
AEI Technologies
| MOXUS Modular Metabolic System |
Download (PDF, 1.5 MB) |
|---|
BTL
| BTL-08 ECG |
Download (PDF, 1.6 MB) |
|---|
Cardiolex
| EC Sense |
Download (PDF, 1 MB) |
|---|
Carewell
| T12 |
Download (PDF, 12.5 MB) |
|---|
Cognimed
| TM Cardio 1000/2000 |
Download (PDF, 1.5 MB) |
|---|
Cortex
| Metasoft |
Download (PDF, 1.5 MB) |
|
|---|---|---|
| Metasoft Studio |
Download (PDF, 1.1 MB) |
Cosmed
| Quark CPET |
Download (PDF, 1.2 MB) |
|
|---|---|---|
| K5 |
Download (PDF, 1.2 MB) |
|
| Quark RMR |
Download (PDF, 1.2 MB) |
|
| Quark PFT |
Download (PDF, 1.2 MB) |
custo med
| Custo Diagnostic Stress ECG |
Download (PDF, 1.7 MB) |
|---|
Delmar Reynolds
| Cardio Collect 12 |
Download (PDF, 1.5 MB) |
|---|
Edan Instruments Inc.
| Edan EC-12 EXPRESS |
Download (PDF, 1.5 MB) |
|
|---|---|---|
| Edan ST-1212 STRESS ECG |
Download (PDF, 1.5 MB) |
Enverdis GmbH
| Cardiologic Explorer 12C Ergo |
Download (PDF, 1.5 MB) |
|---|
ET Medical
| Cubestress |
Download (PDF, 1.7 MB) |
|---|
GE Healthcare
| Cardiosoft |
Download (PDF, 1.5 MB) |
|
|---|---|---|
| Cardiosoft + Corina |
Download (PDF, 1.5 MB) |
|
| Cardiosoft MAC 1200 ST |
Download (PDF, 1.5 MB) |
|
| GE Case |
Download (PDF, 1.5 MB) |
|
| GE Case 8000 |
Download (PDF, 1.5 MB) |
|
| GE Case Basic |
Download (PDF, 1.5 MB) |
|
| GE Case Performance |
Download (PDF, 1.5 MB) |
|
| GE Case Premium |
Download (PDF, 1.5 MB) |
|
| GE Case Value |
Download (PDF, 1.5 MB) |
Korr Medical Technologies Inc
| Cardio Coach Monitor |
Download (PDF, 1.5 MB) |
|---|
Labtech
| EC12 R/S |
Download (PDF, 1.6 MB) |
|---|
Med-tronik
| Lactware Software |
Download (PDF, 1.8 MB) |
|---|
Medical Graphics
| BreezeSuite Software |
Download (PDF, 1.6 MB) |
|---|
Medset
| Flashlight |
Download (PDF, 1.7 MB) |
|---|
Mesa Medizintechnik
| Cardiax PC-EKG |
Download (PDF, 1.5 MB) |
|---|
Mortara
| X-scribe |
Download (PDF, 1.6 MB) |
|---|
Neurosoft
| Poly Spectrum |
Download (PDF, 1.6 MB) |
|---|
Nihon Kohden
| 1350K |
Download (PDF, 1.5 MB) |
|
|---|---|---|
| 1500 K / 1550K - Cardiofax V |
Download (PDF, 1.5 MB) |
|
| 9320K |
Download (PDF, 1.5 MB) |
Norav
| PC-ECG 1200 |
Download (PDF, 1.5 MB) |
|---|
nSpire Health
| 600 USB system |
Download (PDF, 1.6 MB) |
|---|
Parvomedics
| TrueOne |
Download (PDF, 1.7 MB) |
|---|
Philips Medical
| StressVue |
Download (PDF, 1.6 MB) |
|
|---|---|---|
| ST80i - A.03.00 |
Download (PDF, 1.2 MB) |
Progetti
| MyStress system |
Download (PDF, 1.5 MB) |
|---|
Pulse Biomedical, Inc.
| QRS-card |
Download (PDF, 1.6 MB) |
|---|
Quinton
| Q-Stress |
Download (PDF, 1.5 MB) |
|---|
Schiller
| AT-10 |
Download (PDF, 1.5 MB) |
|
|---|---|---|
| AT10 Plus |
Download (PDF, 1.5 MB) |
|
| AT-104 PC |
Download (PDF, 1.5 MB) |
|
| AT-110 |
Download (PDF, 1.5 MB) |
|
| CS200 |
Download (PDF, 1.5 MB) |
Seiva
| Ergolog |
Download (PDF, 1.8 MB) |
|---|
Vyaire
| MasterScreen® ECG / Viasys Oxycon Pro |
Download (PDF, 1.7 MB) |
|
|---|---|---|
| Vyntus CPX / SentrySuite as from 2.17 software |
Download (PDF, 1.7 MB) |
Welch Allyn
| CardioPerfect |
Download (PDF, 1.6 MB) |
|---|